System such as leaks and buckling increase if installed directly over wood board decks.
Malarkey roofing shingle installation instructions.
1 malarkey laminate shingle installation instructions.
Malarkey recommends removing the existing roof covering for best performance and appearance.
Install drip edge first along the eaves and later on the rakes once the field underlayment has been applied.
Complete shingle installation above the plumbing stack flashing.
Underlayment malarkey makes two types of underlayment the first being water resistant mechanically attachedfield underlayments right start udl and our secure start.
Do not apply shingles on roofs having a slope less than 2 51 mm per 12 305 mm.
Drip edge flashing in accordance with 2015 international building code section 1507 2 9 3 and 2015 international residential building code section r905 2 8 5 install non corrosive 26 gauge sheet.
Apply flashing materials in concert with the shingle installation procedure with both the flashing and the shingles arranged to work together to protect around the joint areas.
Fasten as described above.
Prepare the roof deck for applica tion of starter shingles by installing drip edge flashing at the eaves followed by malarkey underlayment or equivalent and then additional flashing along rake edges once underlayment is in place.
Failure to use properly condi tioned deck materials can result in deck movement which can damage the roof covering and may void your warranty.
Flashing is placed around plumbing stacks and vents to help prevent leaks.
See figure 4 eave metal roof deck double layer of specified underlayment rake metal installed on top.
1 malarkey laminate shingle installation instructions.
Preparing the roof deck.
Ensure the outside fasteners are approximately 1 25 mm from each edge.
When re covering an existing shingle roof evaluation of the.
Malarkey s shingle installation instructions require hand sealing shingles on slopes greater than 21 12 and strongly recommend it in adverse weather conditions when cold weather high winds and blowing dust can prevent a shingle s self sealing strip s from activating.
Be sure to overlap the eave drip edge too.
Use five 5 fasteners for each shingle evenly spaced across the shingle and placed within the high nailing area designated by the parallel nailing lines.
3 malarkey windsor designer shingle installation instructions nailing pattern.
Install malarkey laminate shingles according to build ing code and local for the rake drip edge start at the corner near the eave and work your way up lapping subsequent lengths of flashing over the lower pieces by a minimum of 2 51 mm.